Polypropylene Pleated Water Filters

Two numbers describe this cartridge’s pressure rating: 4 bar at 21 °C, and 2.4 bar at 80 °C. Most specifications publish only the first. The second is the one that decides whether a housing is sized correctly, because a polypropylene pleat pack gives up roughly 40 percent of its differential pressure capability across that span.

The PPM element is a depth-loading pleat pack rather than a surface-loading one, so particles are captured through the thickness of the media instead of across its face. Ten grades from 0.1 to 100 µm, on a 2.7″ (69 mm) body in 10″, 20″, 30″ and 40″ lengths, with five seal materials.

Micron Rating
0.1–100 µm
Flow Rate
1–5 GPM per 10"
Max Temperature
80°C
SKU
PPM
  • Depth-loading pleat pack — captures through the media, not across its face
  • Pressure published at two temperatures — 4 bar at 21 °C, 2.4 bar at 80 °C
  • Five seal materials including encapsulated FEP
  • Ten grades from 0.1 to 100 µm
  • Integrity tested, cleanroom produced
  • ISO 9001 with batch documentation on request

Why Choose Pullner Filter?

More than just a supplier – we’re your technical partner in filtration solutions

Laboratory and Testing Facilities

In-house testing capabilities for materials and quality assurance with advanced equipment and certified technicians.

  • Particle counting analysis
  • Pressure drop testing
  • Material compatibility testing

Design and R&D Services

Position as technical partner, not just supplier. Custom solutions for your unique challenges.

  • Custom filter design
  • System optimization
  • Technical consultation

Free Services

Comprehensive free services to support your filtration needs without any hidden costs.


  • Free testing for filtration systems
  • Free custom filtration design
  • Up to 2 free samples

Global Manufacturing

State-of-the-art manufacturing facilities with worldwide delivery capabilities and local support.

  • ISO 9001 certified facilities
  • Global logistics network
  • Local technical support
Scroll to Top
Scroll to Top Update cookies preferences

Speak To Our Engineers

Form Completion
0%