Photoresist Terminal Filter Cartridge, PRFF/PRFN/PRFU Series
The PRFF/PRFN/PRFU photoresist terminal filter cartridge provides terminal photoresist filtration for process engineers, with grades from 0.02 to 10 µm and max pressure drop of 4 bar at 21°C. Send your current element or housing model and operating conditions for a fit check or quote.
- Micron Rating
- 0.02-10 µm
- Max Pressure Drop
- 4 bar
- Max Temperature
- 70°C
- Material
- PTFE, Nylon
- Size
- 2.7" OD · 5/10/20"
Photoresist Terminal Filter Cartridge for Terminal Filtration
PRFF, PRFN and PRFU are the photoresist series in Pullner's pleated filter cartridge range.
How it works: PTFE or nylon membrane captures colloidal particles in photoresist, while the pure PP cage keeps precipitation and dissolution low.
Key features:
- Grades from 0.02 to 10 µm accommodate different filtration requirements.
- The PTFE membrane and PP cage use no adhesives or surfactants to control ion precipitation.
- Integrity testing applies to the PRFF/PRFN/PRFU Series.
Applications:
- Electronics: terminal filtration of photoresist.
- Electronics: colloidal particle removal from photoresist.
- Electronics: photoresist filtration with low ion precipitation.
| Series | PRFF/PRFN/PRFU |
| Micron Rating | 0.02-10 µm |
| Material | PTFE (PRFF), NY66 (PRFN), UPE (PRFU) |
| Cage / Core / End Caps | PP / HDPE |
| Outer Diameter | 2.7" (69 mm) |
| Length | 5", 10", 20" |
| End Connection | 222 flat |
| Seal Material | EPDM, FEP, F-FKM |
| Max Pressure Drop | 4 bar @ 21°C; 2.4 bar @ 70°C |
| Max Temperature | 70°C |
| Certifications | Cleanroom production, integrity tested, ISO 9001 |
Engineers Specifying PRFF, PRFN or PRFU
Process engineers choose membrane and grade together for terminal photoresist filtration.
PRFF/PRFN/PRFU Operating Conditions and Fit
- Micron ratings range from 0.02 to 10 µm.
- Max pressure drop is 4 bar at 21°C and 2.4 bar at 70°C.
- Max temperature is 70°C.
- OD is 2.7" (69 mm).
- Lengths are 5", 10" or 20".
- The end connection is 222 flat.
- Seal options are EPDM, FEP or F-FKM.
Related Pullner Products for Process Water
For process water, Pullner offers the PLPE Series Process Water Filter Cartridge.
What to Send for a Photoresist Cartridge Quote
Fluid, flow rate, micron rating, temperature, pressure, current element or housing model, quantity and timeline.
Which Membrane Does Each Series Use?
PRFF uses PTFE membrane, PRFN uses NY66 nylon and PRFU uses UPE. The PRFF/PRFN/PRFU Series has a 2.7" OD and a 222 flat end connection.
How Fine Do PRFF, PRFN and PRFU Grades Go?
Grades run from 0.02 to 10 µm across the PRFF/PRFN/PRFU Series. Pullner can also customize the grade according to your application and filtration requirements for photoresist.
What PRFF/PRFN/PRFU Limits Apply at 70°C?
Max temperature for the PRFF/PRFN/PRFU Series is 70°C. Max pressure drop is 2.4 bar at that temperature, compared with the published limit of 4 bar at 21°C.